ThermoStar® GSD 350 T
Select the smallest mass range with which the set measuring tasks can be performed. This ensures maximum sensitivity.
Product description
- Gas inlet with quartz capillary, continuously open
ThermoStar® GSD 350 T1, 1 – 100 u
- Mass range 1 – 100 u
- Standard devices with heatable capillary hose up to 200 °C
- Variants with heatable capillary hose up to 350 °C
- Filament material: choose between tungsten or Y2O3-coated iridium
- Variants for corrosive gases
Filament |
Gas connection: Length [m] |
Operating temperature: capillary, up to [°C] |
Calibration unit |
Corrosive gas version |
Part number |
Iridium coated with Y2O3 |
1 |
200 |
No |
No |
PT Q90 211 110 |
|
Tungsten |
1 |
200 |
No |
No |
PT Q90 611 110 |
|
Iridium coated with Y2O3 |
2 |
200 |
No |
No |
PT Q90 211 210 |
|
Tungsten |
2 |
200 |
No |
No |
PT Q90 611 210 |
|
Iridium coated with Y2O3 |
1 |
350 |
No |
No |
PT Q90 211 310 |
|
Tungsten |
1 |
350 |
No |
No |
PT Q90 611 310 |
|
ThermoStar® GSD 350 T2, 1 – 200 u
- Mass range 1 – 200 u
- Standard devices with heatable capillary hose up to 200 °C
- Variants with heatable capillary hose up to 350 °C
- Filament material: choose between tungsten or Y2O3-coated iridium
- Variants for corrosive gases
Filament |
Gas connection: Length [m] |
Operating temperature: capillary, up to [°C] |
Calibration unit |
Corrosive gas version |
Part number |
Iridium coated with Y2O3 |
1 |
200 |
No |
No |
PT Q90 211 120 |
|
Tungsten |
1 |
200 |
No |
No |
PT Q90 611 120 |
|
Iridium coated with Y2O3 |
2 |
200 |
No |
No |
PT Q90 211 220 |
|
Tungsten |
2 |
200 |
No |
No |
PT Q90 611 220 |
|
Iridium coated with Y2O3 |
1 |
350 |
No |
No |
PT Q90 211 320 |
|
Tungsten |
1 |
350 |
No |
No |
PT Q90 611 120 |
|
ThermoStar® GSD 350 T3, 1 – 300 u
- Mass range 1 – 300 u
- Standard devices with heatable capillary hose up to 200 °C
- Variants with heatable capillary hose up to 350 °C
- Filament material: choose between tungsten or Y2O3-coated iridium
- Variants with calibration device for calibrating the mass scale
- Variants for corrosive gases
Filament |
Gas connection: Length [m] |
Operating temperature: capillary, up to [°C] |
Calibration unit |
Corrosive gas version |
Part number |
Iridium coated with Y2O3 |
1 |
200 |
No |
No |
PT Q90 211 130 |
|
Tungsten |
1 |
200 |
No |
No |
PT Q90 611 130 |
|
Iridium coated with Y2O3 |
2 |
200 |
No |
No |
PT Q90 211 230 |
|
Tungsten |
2 |
200 |
No |
No |
PT Q90 611 230 |
|
Iridium coated with Y2O3 |
1 |
350 |
No |
No |
PT Q90 211 330 |
|
Tungsten |
1 |
350 |
No |
No |
PT Q90 611 330 |
|
Iridium coated with Y2O3 |
1 |
200 |
Yes |
No |
PT Q90 111 130 |
|
Tungsten |
1 |
200 |
Yes |
No |
PT Q90 511 130 |
|
Iridium coated with Y2O3 |
2 |
200 |
Yes |
No |
PT Q90 111 230 |
|
Tungsten |
2 |
200 |
Yes |
No |
PT Q90 511 230 |
|
Iridium coated with Y2O3 |
1 |
350 |
Yes |
No |
PT Q90 111 330 |
|
Tungsten |
1 |
350 |
Yes |
No |
PT Q90 511 330 |
|
ThermoStar® GSD 350 T1C, 1 – 100 u
- Mass range 1 – 100 u
- Standard devices with heatable capillary hose up to 200 °C
- Variants with heatable capillary hose up to 350 °C
- Filament material: choose between tungsten or Y2O3-coated iridium
- Variants for corrosive gases
Filament |
Gas connection: Length [m] |
Operating temperature: capillary, up to [°C] |
Calibration unit |
Corrosive gas version |
Part number |
Iridium coated with Y2O3 |
1 |
200 |
No |
Yes |
PT Q91 211 110 |
|
Tungsten |
1 |
200 |
No |
Yes |
PT Q91 611 110 |
|
Iridium coated with Y2O3 |
2 |
200 |
No |
Yes |
PT Q91 211 210 |
|
Tungsten |
2 |
200 |
No |
Yes |
PT Q91 611 210 |
|
Iridium coated with Y2O3 |
1 |
350 |
No |
Yes |
PT Q91 211 310 |
|
Tungsten |
1 |
350 |
No |
Yes |
PT Q91 611 310 |
|
ThermoStar® GSD 350 T2C, 1 – 200 u
- Mass range 1 – 200 u
- Standard devices with heatable capillary hose up to 200 °C
- Variants with heatable capillary hose up to 350 °C
- Filament material: choose between tungsten or Y2O3-coated iridium
- Variants for corrosive gases
Filament |
Gas connection: Length [m] |
Operating temperature: capillary, up to [°C] |
Calibration unit |
Corrosive gas version |
Part number |
Iridium coated with Y2O3 |
1 |
200 |
No |
Yes |
PT Q91 211 120 |
|
Tungsten |
1 |
200 |
No |
Yes |
PT Q91 611 120 |
|
Iridium coated with Y2O3 |
2 |
200 |
No |
Yes |
PT Q91 211 220 |
|
Tungsten |
2 |
200 |
No |
Yes |
PT Q91 611 220 |
|
Iridium coated with Y2O3 |
1 |
350 |
No |
Yes |
PT Q91 211 320 |
|
Tungsten |
1 |
350 |
No |
Yes |
PT Q91 611 320 |
|
ThermoStar® GSD 350 T3C, 1 – 300 u
- Mass range 1 – 300 u
- Standard devices with heatable capillary hose up to 200 °C
- Variants with heatable capillary hose up to 350 °C
- Filament material: choose between tungsten or Y2O3-coated iridium
- Variants with calibration device for calibrating the mass scale
- Variants for corrosive gases
Filament |
Gas connection: Length [m] |
Operating temperature: capillary, up to [°C] |
Calibration unit |
Corrosive gas version |
Part number |
Iridium coated with Y2O3 |
1 |
200 |
No |
Yes |
PT Q91 211 130 |
|
Tungsten |
1 |
200 |
No |
Yes |
PT Q91 611 130 |
|
Iridium coated with Y2O3 |
2 |
200 |
No |
Yes |
PT Q91 211 230 |
|
Tungsten |
2 |
200 |
No |
Yes |
PT Q91 611 230 |
|
Iridium coated with Y2O3 |
1 |
350 |
No |
Yes |
PT Q91 211 330 |
|
Tungsten |
1 |
350 |
No |
Yes |
PT Q91 611 330 |
|
Iridium coated with Y2O3 |
1 |
200 |
Yes |
Yes |
PT Q91 111 130 |
|
Tungsten |
1 |
200 |
Yes |
Yes |
PT Q91 511 130 |
|
Iridium coated with Y2O3 |
2 |
200 |
Yes |
Yes |
PT Q91 111 230 |
|
Tungsten |
2 |
200 |
Yes |
Yes |
PT Q91 511 230 |
|
Iridium coated with Y2O3 |
1 |
350 |
Yes |
Yes |
PT Q91 111 330 |
|
Tungsten |
1 |
350 |
Yes |
Yes |
PT Q91 511 330 |
|